Chloride-induced corrosion of embedded steel bars deteriorates reinforced concrete structures. This study investigated a static solenoid magnetic field (SSMF) as a means of chloride penetration delaying (CLPD). The SSMF was generated by a coil wound around a threaded steel bar embedded in concrete. Concrete cylinders were exposed to 10% sodium chloride solution for 45 days. 6 current levels were tested, from 0 to 1.0 A. Penetration was assessed via AgNO3 testing. A training-free feed-forward convolutional neural network quantified the affected area. In the specimens tested, the non-penetrated area ratio rose monotonically, from 41.41% at 0.0 A to 63.30% at 1.0 A. The increase followed a stepwise, non-linear trend. Lorentz-force and magnetohydrodynamic mechanisms were shown to be insufficient to explain this effect. Hydration shell perturbation coupled with pore-throat constrictivity is proposed as a candidate mechanism instead. These findings identify a previously undocumented phenomenon. SSMF exposure warrants further mechanistic and replicate investigation.
No takes yet. Share an insight, caveat, or question.
Woo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: