Answers are grounded in this paper and cite their sources.
The spacecraft electrical power system (EPS) is the most failure-critical on-orbit subsystem, while its connecting cable network is an often-overlooked source of degradation. Most methods monitor the two separately and decouple detection from corrective power management. This paper proposes a physics-informed hybrid framework jointly monitoring the EPS power link and cable network and closing the loop with adaptive reconfiguration. A simulator generates 36-channel telemetry over eight operating modes, in which a harness thermal model produces wire-temperature, contact hot-spot, and voltage-drop residuals invisible to power-only sensing. A dual-residual detector fuses a mode-conditioned physics residual with an autoencoder reconstruction residual via an OR rule and three-sample persistence. On 102 episodes spanning 17 fault types (11 power-side, 6 cable-side), it reaches a recall of 0.98 (100/102) with zero false alarms on held-out nominal data, matching an autoencoder-only detector, whereas the physics-only and rule baselines reach 0.51 and 0.47; a random forest attributes the fault class (accuracy 0.465, macro-F1 0.448). Under a 28% under-supply fault, minimal-load MPC reconfiguration retains 0.720 of load power versus 0.636 for rule-based shedding and near-zero in open loop. Joint harness-aware monitoring with minimal reconfiguration offers a simulation-validated basis for autonomous EPS health management, pending cross-simulator and hardware-in-the-loop confirmation.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: