Answers are grounded in this paper and cite their sources.
This paper introduces a standardized, minimally invasive semidestructive testing (SDT) protocol for assessing concrete–rebar bond strength in in-service concrete structures, for which no standardized testing procedure currently exists. The protocol involves pullout testing of rebars embedded in machine-trimmed concrete cores extracted from the assessed structure and tested under constrained and unconstrained conditions to establish a linear bond–confinement model. This model is used to interpolate in situ bond strength based on confinement conditions identified from site investigations. The testing setup was calibrated through pilot testing of 36 cast cores with varying concrete strengths, rebar sizes, and rebar eccentricities, resulting in calibrated core confinement factors and bond strength correction factors that account for setup imperfections. The protocol was applied to two 50-year-old cope walls—with alkali-silica reaction damage—at an existing port in Halifax, Canada, and validated via in situ pullout tests. Under field confinement and known embedment, the core-based bond strength was statistically representative of the mean in situ strength, confirmed using Kolmogorov–Smirnov test at 5% significance. Results indicated that bond strength loss in cope walls exceeds 3%. Standardized testing procedures, limitations, and recommendations for real-life applications are presented.
No takes yet. Share an insight, caveat, or question.
Modi et al. (2026) studied this question.