Freeform ophthalmic lens manufacturing requires compensation for prescription-dependent deviations and process drift. This study retrospectively evaluates an order-to-order compensation method combining ensemble prediction, exponentially weighted moving average (EWMA), residual tracking, and a proposed material-specific three-level gate. The 2245 manufacturing records are partitioned by whole chronological days into training (1356), validation (484), and final-test (405) sets. Thirteen models are compared, with controller settings selected using validation data only. Under unit-gain replay, joint pass rates for spherical and cylindrical power deviations within the study-specific ±0.10 D band are 57.04% without added compensation, 68.40% with historical fixed-offset correction, 75.06% with static AI, 65.43% with pure EWMA, 74.81% with global AI + EWMA, and 76.54% with material-specific tracking and the gate. The material strategy gains 19.51 percentage points over the baseline (95% date-bootstrap interval: 14.57–25.70). Paired intervals comparing material tracking with static AI and global fusion include zero in the robustness analysis. Global fusion achieves higher joint pass rates than static AI in all five expanding-window evaluations under the robustness protocol. The gate remains FULL in the primary replay, producing identical commands to ungated tracking; one material performs below the baseline. These findings motivate prospective assessment of machine response, manufacturing yield, and gate protection.