Answers are grounded in this paper and cite their sources.
A design concept for an adaptive starter-generator system (SGS) is proposed, in which a synergistic effect, namely, an increase in the generated three-phase AC power and an improvement in its quality is achieved through the use of the cycloconverter with natural commutation and the transistor inverter with high-frequency PWM, operating as an active filter and a DC voltage source. Two topologies of six-pulse cycloconverter power circuit for use in the SGS based on a six-phase permanent-magnet synchronous generator are considered. Their advantages and disadvantages are identified. The block diagram of the control system for the cycloconverter based on the cascade control principle and vector control algorithms in a rotating reference frame is proposed. A zero-sequence output voltage loop is introduced, which extends the power range under unbalanced loads. For the proposed topologies of the cycloconverter, equivalent circuits based on the "sliding" average of the output voltage and current are proposed. Analytical expressions for the converter transfer coefficients are derived. The block diagrams of the current and voltage controllers are considered. A parametric synthesis procedure is presented, and the stability regions are determined. The differences and similarities in the controller structures for the two considered power circuit topologies are revealed. A possible algorithm for implementing a separate control unit for the cycloconverter is proposed.
No takes yet. Share an insight, caveat, or question.
Sarakhanova et al. (2026) studied this question.