Key result
Transseptal puncture in ACHD ablation can trigger severe hypoxemia via right-to-left iASD shunting requiring closure.
Why the study?
Right-to-left shunting through an iatrogenic atrial septal defect is a rare but potentially serious complication following transseptal puncture during catheter ablation, and elevated right atrial pressure in patients with adult congenital heart disease may predispose to this complication.
Case Report (n=2)
Answers are grounded in this paper and cite their sources.
Patients with adult congenital heart disease and elevated right atrial pressure are at risk for severe hypoxemia from right-to-left shunting across an iatrogenic atrial septal defect after transseptal puncture, underscoring the need for preprocedural echocardiographic risk stratification and readiness for transcatheter closure.
Right-to-left (RL) shunting through an iatrogenic atrial septal defect (iASD) is a rare but potentially serious complication following transseptal puncture (TSP) during catheter ablation. Here, we report the cases of two patients with adult congenital heart disease (ACHD) who developed severe hypoxemia due to RL shunting through iASD after catheter ablation, both ultimately requiring transcatheter closure because of persistent postoperative desaturation. Case 1 involved a 70-year-old woman with repaired double-chambered right ventricle, prior ventricular septal defect repair, and abnormal chordal resection who developed oxygen desaturation after atrial fibrillation ablation; retrospective echocardiographic review revealed findings suggestive of an elevated right atrial pressure in association with severe tricuspid stenosis. Case 2 involved a 69-year-old man with untreated Ebstein's anomaly and suspected Loeffler's endocarditis who developed clinically significant hypoxemia after ablation for drug-refractory atrial tachycardia. Preprocedural echocardiography demonstrated severe tricuspid regurgitation and prominent end-diastolic forward flow in the pulmonary artery, suggesting susceptibility to RL shunting through an iASD after TSP. These cases highlight the importance of detailed preprocedural echocardiographic risk stratification, careful perioperative monitoring, prompt recognition of postprocedural hypoxemia, and timely consideration of transcatheter closure in patients with ACHD undergoing catheter ablation involving TSP. Learning objective Catheter ablation for tachyarrhythmia with adult congenital heart disease can affect long-term outcomes. However, elevated right atrial pressure may cause right-to-left shunting through an iatrogenic atrial septal defect after transseptal puncture. Although rare, this can lead to severe hypoxemia requiring transcatheter closure. Preprocedural echocardiography can identify high-risk patients, guide perioperative planning to reduce complications, and facilitate interventions.
No takes yet. Share an insight, caveat, or question.
Okidono et al. (2026) conducted a case report in Adult congenital heart disease (ACHD) with tachyarrhythmia undergoing catheter ablation with transseptal puncture (n=2). Catheter ablation involving transseptal puncture (followed by transcatheter closure of iASD) was evaluated on Severe hypoxemia due to right-to-left shunting through an iatrogenic atrial septal defect requiring transcatheter closure. Catheter ablation with transseptal puncture in 2 patients with adult congenital heart disease caused severe hypoxemia from right-to-left iASD shunting, requiring transcatheter closure in both.
Synapse has enriched 10 related papers. Consider them for comparative context: