Answers are grounded in this paper and cite their sources.
Offshore floating photovoltaics could expand solar generation in marine areas, but its economic viability needs to be assessed. This paper presents a methodology that combines geographic, technological and economic data to map the net present value (NPV), internal rate of return (IRR) and levelised cost of energy (LCOE) of offshore floating photovoltaic farms, and applies it to three platforms (Ocean Sun, SOcean and Merganser) in the Spanish South Atlantic marine demarcation under four scenarios of installed capacity (about 6.4 and 12.8 MW) and electricity tariff (€0.1199 and €0.187375/kWh). None of the platforms reaches positive returns: the IRR of the financed project stays below the weighted average cost of capital (7.1–7.8%) and the NPV is negative at every location. Ocean Sun is the least unfavourable, with mean LCOEs of 313–391 €/MWh, followed by Merganser (351–428 €/MWh) and SOcean (896–965 €/MWh), whose CAPEX per MW is much higher. Doubling the capacity lowers the LCOE and raises the IRR, but makes the total NPV more negative. A CAPEX sensitivity analysis identifies the main cost drivers of each platform. Given the simplified assumptions, the results are baseline estimates, not operational forecasts.
No takes yet. Share an insight, caveat, or question.
Damera-Figueredo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: