Inertial measurement units (IMUs) provide a portable and infrastructure-free solution for human motion capture, but accumulated integration errors lead to substantial drift during continuous motion. This paper presents a wearable device for human motion capture using wireless IMU sensing nodes and a constraint-aided error-state Kalman filtering framework. For lower-limb motion capture, three IMU nodes are placed on the pelvis and bilateral ankles to reduce the number of body-worn sensors. Zero-velocity updates are applied during detected stance phases, and biomechanical constraints are introduced to suppress inertial drift and improve motion consistency. Closed-loop walking experiments and Vicon-referenced evaluation demonstrate that the proposed device achieves a relative trajectory drift of 2.64% and an overall root-mean-square error (RMSE) of 15.334 mm, together with improved biomechanical consistency. The proposed device provides a practical solution for wearable motion capture with sparse sensor deployment.