Answers are grounded in this paper and cite their sources.
Production gear inspection reports standard profile and lead deviations, but the amount of information retained in the dispersion of the displayed values beyond scalar magnitude is less clear. This study analyzes 65 inspection reports from 59 production helical gears with 23 teeth, comprising 4680 audited cell values; 4248 values from the latest report per component define the primary population. Six standard report parameters were separated from author-defined summaries of pooled magnitude, sampled dispersion, concentration, and flank asymmetry. Lead-form deviation ffβ showed the strongest magnitude–variability association: magnitude versus mean trace SD gave Spearman ρ = 0.738 (95% component-bootstrap CI 0.544–0.868), and magnitude versus normalized variability gave ρ = 0.675 (0.450–0.832). Total profile deviation Fα magnitude versus SD gave ρ = 0.618 (0.399–0.785). An empirical scale-coupling null indicated that the principal associations exceeded those expected from randomly pairing observed magnitudes with observed relative-shape factors. However, the six displayed positions are not verified sequential teeth; the localization statistic is sensitive to individual readings, and no exact same-part rolling-test records are available. The vibration-related mappings are therefore testable hypotheses for future matched-part validation, not demonstrated geometry-to-vibration transfer.
No takes yet. Share an insight, caveat, or question.
Horváth et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: