Data on the coronal volume removed by endocrown preparations are lacking. This in silico study quantified this volume as a function of occlusal reduction, pulp chamber extension depth, and peripheral preparation design. Four idealized parametric tooth models (two premolars, two first molars) were prepared by Boolean subtraction with three occlusal reductions (1.5–3.0 mm), three extension depths (2–4 mm), and four peripheral designs (butt joint; heavy chamfer and 1.0 and 2.0 mm shoulders with a 1.5-mm axial component), yielding 144 experimental preparations and eight reference models (intact and endodontic access). Volumes were cross-checked in 3D Slicer and analyzed descriptively. Removal relative to the intact model was 8.9–59.3 vol%. Within this deterministic factorial design, occlusal reduction accounted for 70–77% of the variation (descriptive sums-of-squares partition), peripheral design for 20–30%, and extension depth for 0.3–3.4%. The 2.0-mm shoulders removed 14–19 percentage points more than butt joints and left 0.2–0.8-mm residual walls. Relative to the endodontic access reference, 12–70% of the removed volume overlapped the access space, and extension depth contributed ≤0.06 percentage points of additional removal. Occlusal reduction was the primary determinant, followed by peripheral design; extension depth had a limited effect. These volumetric findings do not establish mechanical performance or clinical safety.
No takes yet. Share an insight, caveat, or question.
YAPALAK et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: