Answers are grounded in this paper and cite their sources.
Three-dimensional unsteady numerical simulations were performed to investigate detonation-wave propagation, pressure response, and outlet thermal characteristics in fully premixed gaseous-kerosene/air disk-shaped rotating detonation combustors with and without guide vanes over a range of inlet total temperatures. The novelty of this study is a unified comparison that links guide-vane-induced outlet constraint and upstream pressure feedback to changes in propagation mode, pressure-wave/reaction-zone coupling, and outlet temperature distortion in the same three-dimensional disk-shaped combustor. The unvaned configuration maintained stable single-wave propagation from 550 to 750 K. At 850 K, the leading pressure wave gradually separated from the high-temperature heat-release zone, and the detonation ultimately decoupled and became unstable. The vaned configuration remained predominantly in a single-wave mode from 550 to 700 K but transitioned to a two-wave mode at 750 K. Blockage at the vane leading edges and contraction of the vane passages increased the instantaneous flow resistance at the combustor outlet. The resulting upstream feedback of compression waves and reflected shocks interacted with the fresh mixture ahead of the wave, causing local recompression and temperature rise and modifying the coupling between the pressure wave and the heat-release zone. At 750 K, the newly formed high-pressure regions corresponded closely to regions of intense local reaction. Time-resolved pressure, temperature, and fuel-mass-fraction fields further showed the development from one mature front with a strengthening secondary disturbance to two persistent pressure-reaction coupled fronts. For the unvaned configuration, the outlet temperature distortion factor (OTDF) first decreased and then increased with inlet total temperature, reaching a minimum of approximately 0.504 at 650 K. For the vaned configuration, the OTDF decreased to a minimum of approximately 0.190 at 700 K. Under the same 750 K condition, the guide vanes reduced the OTDF from 0.612 to 0.218. Thus, guide-vane constraint reorganized the internal wave system and shifted the condition associated with the best outlet thermal uniformity from 650 K without guide vanes to 700 K with guide vanes. The OTDF values are based on phase-matched instantaneous total-temperature fields and mass-flow-weighted mean total temperatures. The unvaned and vaned values are sampled at the combustor exit and immediately upstream of the guide-vane leading edges, respectively.
No takes yet. Share an insight, caveat, or question.
Liang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: