Answers are grounded in this paper and cite their sources.
Robotic-assisted TKA (RATKA) using a functional alignment (FA) approach enables patient-specific rotational planning, but its effect on femoral rotational accuracy remains uncertain. This study evaluated femoral rotational planning–execution fidelity with RATKA using a FA approach and characterized femoral rotational profiles and early clinical outcomes following robotic FA and conventional TKA. This retrospective single-center study included consecutive patients undergoing TKA for end-stage osteoarthritis (OA: grade 3 and 4). Patients underwent RATKA using the fully automated MISSO joint robot with CT-based preoperative planning to individualize femoral component rotation relative to the transepicondylar axis (TEA) and posterior condylar axis (PCA), aiming to balance flexion gaps without soft tissue releases. The conventional group underwent standard TKA targeting neutral alignment and a fixed 3° external femoral rotation. All procedures were performed by the same surgical team using the same posterior-stabilized implant. Clinical outcomes were assessed at one year [Knee Society Score (KSS) and Oxford Knee Score (OKS)]. The RATKA group ( n = 50) demonstrated a mean planning–execution deviation of 0.7° ± 1.3° based on robotic execution data. The postoperative rotational profile in the RATKA group showed mean external rotation of 1.5° ± 1.0° relative to the TEA and 2.4° ± 2.2° relative to the PCA. In the conventional group ( n = 50), the mean deviation of 1.8° ± 1.5° from the intended rotational target was noted. The postoperative rotational profile in this group showed mean external rotation of 0.2° ± 1.2° relative to the TEA and 3.1° ± 1.0° relative to the PCA. Postoperative HKA was 1.8° ± 2.5° varus in the RATKA group and 0.5° ± 2.7° varus in the conventional group. At one-year follow-up, no patellofemoral complications or early loosening were observed in either group. KSS and OKS improved significantly in both groups, with no significant between-group differences. RATKA using an FA approach demonstrated close planning–execution fidelity for individualized femoral rotation, with both RATKA and conventional TKA achieving acceptable limb alignment and favorable short-term clinical outcomes. As rotational outcomes were assessed using different methods, conclusions regarding comparative rotational accuracy could not be drawn. Future studies using uniform postoperative CT-based assessment are required to establish comparative accuracy and its clinical relevance.
No takes yet. Share an insight, caveat, or question.
Rudraraju et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: