Key result
ED CIED interrogation linked to prolonged consult-to-disposition time, reaching ~13 hours vs un-interrogated consults.
Why the study?
Patients with CIEDs frequently present to the emergency department with device-related complaints, but whether device interrogation represents a bottleneck to disposition had not been systematically studied.
Does cardiac implantable electronic device interrogation in the emergency department prolong time to disposition and increase likelihood of hospital admission compared to cardiology or electrophysiology consultations without interrogation in patients with CIEDs?
Cohort (n=479)
Yes
Does cardiac implantable electronic device interrogation in the emergency department prolong time to disposition and increase likelihood of hospital admission compared to cardiology or electrophysiology consultations without interrogation in patients with CIEDs?
Answers are grounded in this paper and cite their sources.
Emergency department CIED interrogation acts as a significant operational bottleneck that prolongs time from consultation to disposition (particularly after hours) and is independently associated with increased hospital admission rates.
Objectives: Patients with cardiac implantable electronic devices (CIEDs), such as pacemakers and implantable cardioverter-defibrillators, frequently present to the emergency department (ED) with complaints potentially attributable to their devices. Device interrogation can characterize arrhythmias and guide management, but whether it represents a bottleneck to disposition has not been systematically studied. Methods: Retrospective cohort study at two academic centers (2024-2026). Visits were identified via consultations. Control cohorts of patients with general cardiology and EP consultations with pacemakers were propensity score matched. Intervals were compared via Kruskal-Wallis tests. Logistic regression investigated associations between demographic factors, time intervals, and admission. Results: We identified 677 visits from 479 unique patients involving CIED-related EP consultation. The median ED length of stay (LOS) was 24.3 hours (IQR 10.2-36.1), with 80.4% admitted. General cardiology and EP consults without interrogation demonstrated similar times to consultation (4.0 [IQR 1.8-11.1] and 3.0 [IQR 0.9-12.4], p=0.4 and p=0.1), but shorter from consult to disposition (13.3 hours [IQR 12.7-14.4] vs. 5.2 [IQR 4.5-5.9] and 6.8 [IQR 6.0-7.5], both p<0.001). Consults with interrogation after hours were prolonged (14.9 [IQR 7.1-20.5] vs 7.1 [IQR 5.4-11.1], p<0.001). In the logistic regression, longer consultations were associated with higher likelihood of admission (aOR 1.05, 95% CI 1.02-1.07 per hour). No other factors were significant. Conclusion: Patients requiring CIED interrogation experienced delays relative to other patients, with interrogation as the proximate step before disposition. Consults after hours took longer, and delays were independently associated with admission. These findings highlight an operational bottleneck in acute CIED management, and efforts to expedite device interrogation warrant further investigation.
No takes yet. Share an insight, caveat, or question.
Joseph et al. (2026) conducted a cohort in Cardiac implantable electronic devices (CIEDs) presenting to the emergency department (n=479). CIED interrogation during electrophysiology consultation vs. General cardiology and electrophysiology consultations without device interrogation was evaluated on Time from consultation to emergency department disposition (hours) (aOR 1.05 per hour for hospital admission, 95% CI 1.02-1.07, p=<0.001). CIED interrogation in the ED prolonged consult-to-disposition time versus general cardiology or EP consults without interrogation.