Key result
Robotic STA-MCA bypass achieves 100% patency and improves cerebral perfusion in a first-in-human case.
Why the study?
The Symani Surgical System is CE-marked for extracranial surgery, and this study evaluated the technical feasibility and clinico-radiological outcomes of extending its use to perform an intracranial anastomosis during an STA-MCA bypass.
Is robotic-assisted intracranial anastomosis using the Symani Surgical System technically feasible and effective in achieving bypass patency and improved cerebral perfusion in a patient with internal carotid artery occlusion undergoing STA-MCA bypass?
Case Report (n=1)
No
Is robotic-assisted intracranial anastomosis using the Symani Surgical System technically feasible and effective in achieving bypass patency and improved cerebral perfusion in a patient with internal carotid artery occlusion undergoing STA-MCA bypass?
This case report demonstrates the technical feasibility and successful clinico-radiological outcome of extending the Symani Surgical System to perform an intracranial anastomosis during an STA-MCA bypass.
Answers are grounded in this paper and cite their sources.
Extends robotic microsurgery to intracranial anastomosis; leaves open safety, efficacy, and adoption pending prospective data.
The Symani Surgical System is CE-marked for extracranial surgery. We report its extension, within the same surgical field, to the execution of an intracranial anastomosis during a superficial temporal artery–middle cerebral artery (STA-MCA) bypass, describing its technical feasibility and clinico-radiological outcomes. A 49-year-old woman with left intracranial internal carotid artery occlusion, presenting with recurrent transient ischemic attacks of increasing frequency and compromised cerebrovascular reserve, underwent extra-intracranial STA-MCA bypass. The robotic system, already employed for extracranial donor vessel preparation in accordance with its intended certification, was used seamlessly within the same operative field to perform the intracranial anastomosis. The anastomosis was completed without technical complications, and the postoperative course was uneventful. Immediate and follow-up angiographic and perfusion studies demonstrated bypass patency and a more symmetric cerebral perfusion pattern compared to the preoperative baseline. Extending the use of the robotic system to the intracranial compartment proved technically feasible in this selected case. The tool design is well suited for superficial bypass (STA-MCA), filtering tremor and providing motion scaling. Larger case series are warranted to systematically evaluate its advantages and limitations.
No takes yet. Share an insight, caveat, or question.
Cenzato et al. (2026) conducted a case report in Left intracranial internal carotid artery occlusion with recurrent transient ischemic attacks and compromised cerebrovascular reserve (n=1). Robotic-assisted intracranial superficial temporal artery–middle cerebral artery (STA-MCA) bypass using the Symani Surgical System was evaluated on Technical feasibility, bypass patency, and clinico-radiological outcomes. Robotic-assisted intracranial STA-MCA bypass using the Symani Surgical System achieved 100% bypass patency and improved cerebral perfusion without technical complications in 1 patient.
Synapse has enriched 10 related papers. Consider them for comparative context: