Key result
Pre-procedural CTA improves PDA stent sizing accuracy and axillary access shortens procedure time vs femoral approach.
Why the study?
Patent ductus arteriosus stenting is a viable alternative to surgical shunts for duct-dependent pulmonary blood flow, but optimal pre-procedural imaging for sizing and the choice between femoral and axillary vascular access remain debated.
Does pre-procedural CT angiography and axillary vascular access improve stent sizing accuracy, procedural efficiency, and technical success compared to echocardiography alone and femoral access in neonates and infants undergoing PDA stenting for duct-dependent pulmonary blood flow?
Cohort (n=48)
No
Does pre-procedural CT angiography and axillary vascular access improve stent sizing accuracy, procedural efficiency, and technical success compared to echocardiography alone and femoral access in neonates and infants undergoing PDA stenting for duct-dependent pulmonary blood flow?
In neonates undergoing PDA stenting for duct-dependent pulmonary blood flow, pre-procedural CT angiography predicted stent length more accurately than echocardiography and axillary access reduced procedural time compared to femoral access, though technical success and major complication rates were not statistically different.
Answers are grounded in this paper and cite their sources.
CT angiography and axillary access may enhance efficiency in PDA stenting; hypothesis-generating and requires randomized confirmation before practice change.
Background: Duct-dependent pulmonary blood flow is a critical neonatal emergency. Patent ductus arteriosus (PDA) stenting is a viable alternative to surgical shunts, but optimal pre-procedural imaging for sizing and the choice of vascular access (femoral vs. axillary) remain debated. Aim: This retrospective study aimed to evaluate the degree of agreement between pre-procedural imaging (CT angiography vs. echocardiography) and the final implanted stent dimensions and to evaluate outcomes associated with femoral versus axillary access. Methods: A retrospective cohort study was conducted at the Queen Alia Heart Institute, Jordan, from January 2020 to May 2024. Medical records of neonates and infants who underwent PDA stenting for duct-dependent pulmonary blood flow were reviewed. Patients were categorized by imaging modality (CT angiography vs. echocardiography) and access approach (femoral vs. axillary). Data collected included demographics, ductal morphology, stent dimensions, procedural details, technical success, complications, and post-procedural outcomes. Results: A total of 48 patients (mean age = 11.2 ± 8.4 days; mean weight = 3.2 ± 0.5 kg) were included. CT angiography (n = 22) demonstrated a numerically smaller mean absolute difference in predicting stent length compared to echocardiography (n = 26) (1.1 mm vs. 2.9 mm; p = 0.006), while diameter agreement was comparable. Axillary access (n = 15) was associated with a shorter procedural time compared to femoral access (n = 33) (49 ± 18 vs. 74 ± 29 minutes; p = 0.003). However, there were no statistically significant differences in technical success (14/15 (93.3%) vs. 25/33 (75.8%); p = 0.239) or major complication rates (2/15 (13.3%) vs. 6/33 (18.2%); p = 1.000). Conclusion: In this small retrospective cohort, CT angiography demonstrated a numerical trend toward better prediction of stent length, and axillary access was associated with shorter procedural times. However, these differences were not statistically significant for technical success or safety outcomes. These findings are hypothesis-generating; larger prospective studies are required to confirm whether tailored imaging and access site selection can improve outcomes in this vulnerable population.
No takes yet. Share an insight, caveat, or question.
Al-Bataineh et al. (2026) conducted a cohort in Duct-dependent pulmonary blood flow requiring patent ductus arteriosus (PDA) stenting (n=48). Axillary vascular access (and pre-procedural CT angiography) vs. Femoral vascular access (and echocardiography alone) was evaluated on Procedural technical success (successful stent deployment with adequate angiographic flow without surgical conversion) (p=0.239). CT angiography lowered stent length error vs echocardiography, while axillary access shortened procedure time vs femoral with similar technical success.
Synapse has enriched 10 related papers. Consider them for comparative context: