Key result
Agitated saline contrast increases quantifiable tricuspid regurgitant signals from 20% to 85% in mild TR.
Why the study?
Doppler ultrasound measurement of right ventricular systolic pressure requires a quantifiable tricuspid regurgitation signal, and the utility of intravenous saline echo contrast to increase the percentage of quantifiable signals in patients with detectable tricuspid regurgitation needed evaluation.
Does intravenous agitated saline contrast increase the percentage of quantifiable tricuspid regurgitant signals for right ventricular systolic pressure measurement in patients with detectable baseline tricuspid regurgitation?
Observational (n=60)
Does intravenous agitated saline contrast increase the percentage of quantifiable tricuspid regurgitant signals for right ventricular systolic pressure measurement in patients with detectable baseline tricuspid regurgitation?
Answers are grounded in this paper and cite their sources.
Intravenous agitated saline contrast markedly improves the yield of quantifiable Doppler tricuspid regurgitant signals from 20% to 85% in patients with trace or mild tricuspid regurgitation, enabling reproducible estimation of right ventricular systolic pressure.
Doppler ultrasound has become accepted as a measurement of right ventricular systolic pressure in patients who have a quantifiable signal from tricuspid regurgitation. This study evaluated the use of intravenous injection of saline solution for echo contrast to increase the percentage of quantifiable tricuspid regurgitant signals in patients who have any detectable tricuspid regurgitation at baseline. Patients underwent a standard Doppler evaluation, followed by a contrast study with the injection of 4 to 6 ml of agitated saline solution into a brachial vein. Baseline and contrast tricuspid regurgitant signals were assessed for quality, quantifiability, and reproducibility of the derived pressures by three observers on two occasions. The average absolute pairwise deviation among the three observers was low: 1.6 mm Hg (standard deviation, 1.4 mm Hg). The intraobserver mean discrepancy was low: 0.03 mm Hg (standard deviation, 2.33 mm Hg). Patients who did not have tricuspid regurgitation (n = 10) failed to develop such regurgitation during contrast injection. Only eight of 40 patients (20%) who had trace or mild tricuspid regurgitation had quantifiable baseline signals, but 34 patients (85%) had quantifiable signals with contrast injection. All patients who had mild to moderate, moderate, or severe tricuspid regurgitation (n = 10) had quantifiable signals before contrast injection. Of all patients who had any tricuspid regurgitation, 88% had quantifiable signals with contrast injection. Echo contrast was shown to improve the yield of quantifiable signals in patients who had trace and mild tricuspid.
No takes yet. Share an insight, caveat, or question.
Torres et al. (1989) conducted an observational in Tricuspid regurgitation undergoing right ventricular systolic pressure measurement by Doppler echocardiography (n=60). Intravenous agitated saline solution for echocardiographic contrast vs. Standard baseline Doppler evaluation prior to contrast injection was evaluated on Percentage of quantifiable tricuspid regurgitant signals in patients with trace or mild tricuspid regurgitation. Intravenous agitated saline contrast increased quantifiable tricuspid regurgitant signals from 20% to 85% in patients with trace or mild tricuspid regurgitation.
Synapse has enriched 10 related papers. Consider them for comparative context: