Answers are grounded in this paper and cite their sources.
This study evaluates two hybrid postcombustion CO2 capture configurations and benchmarks them against a net 1000 MW supercritical coal-fired power plant without carbon capture. Case 2 integrates HFMC-based absorption with thermal regeneration in Mellapak structured packing, while case 3 combines Mellapak absorption with vacuum-assisted HFMC regeneration. Detailed absorber and desorber models were developed in MATLAB/Simulink and coupled in Aspen Plus full-plant flowsheets to ensure consistent mass and energy balances, achieving a 90% capture rate. Among the captured assessed systems, case 3 shows the best technical performance, reaching an electrical efficiency of 35.35% and reducing SPECCA to 2.17 MJ/kg CO2, compared with 3.77 MJ/kg CO2 for case 2. Economically, case 3 also provides the lowest levelized cost of electricity, 100.33 €/MWh, and CO2 avoidance cost, 57.50 €/t CO2. The cradle-to-gate Life Cycle Assessment indicates an approximately 74% reduction in global warming potential, although increases occur in other impact categories when competed with the benchmark noncapture configuration, highlighting the trade-offs associated with deep decarbonization. Overall, the results demonstrate that membrane-based regeneration strategies can significantly enhance energy efficiency, together with economic and environmental performance of postcombustion CO2 capture.
No takes yet. Share an insight, caveat, or question.
Bozonc et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: