Answers are grounded in this paper and cite their sources.
This paper computes a detector noise budget for the instrument named in the title, from stated inputs and named formulas, and tests the result against a published value. The calculation finds that the strain sensitivity at 100 hertz is 0.0420 zeptostrain per root hertz, the binary neutron star inspiral range is 130.00 megaparsecs, the binary neutron star horizon distance is 293.80 megaparsecs, the survey volume is 0.00920 cubic gigaparsecs. The ratio of the computed value to the published comparison value is 1.000, so the budget agrees with the published value within the stated uncertainties. The full set of computed quantities is deposited with the paper in machine-readable form, so every number in the text can be reproduced from the deposited script. Computed from stated assumptions, not measured.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: