This paper computes a detector noise budget for the instrument named in the title, from stated inputs and named formulas, and tests the result against a published value. The calculation finds that the ground motion at 10 hertz is 1.000 nanometres per root hertz, the number of isolation stages is 4.000 stages, the test-mass motion at 10.0 hertz is 0.1680 attometres per root hertz, the test-mass motion at 20.0 hertz is 0.000164 attometres per root hertz. The ratio of the computed value to the published comparison value is 1.050, so the budget agrees with the published value within the stated uncertainties. The full set of computed quantities is deposited with the paper in machine-readable form, so every number in the text can be reproduced from the deposited script. Computed from stated assumptions, not measured.