Answers are grounded in this paper and cite their sources.
This paper presents a quantitative and qualitative validation procedure aimed at identifying systematic errors and improving the reliability and repeatability of measurements in industrial and engineering applications. The study focuses on identifying sources of error arising during data acquisition and evaluating the effectiveness of selected strategies for minimising these errors, including calibration, sensor selection, and optimisation of measurement parameters. The main contribution of the study is the standardisation and experimental application of the zero-unitisation method (MUZ), including the adoption of a cumulative index threshold of W_MUZ=0.3 as a criterion for classifying experimental measurement systems as acceptable or conditionally acceptable. The proposed procedure provides unambiguous and reproducible criteria for evaluating measurement-process parameters and enables the comparison of alternative experimental configurations by transforming measured variables into a normalised form. The assessment incorporates both qualitative characteristics, such as accuracy, stability, compliance with nominal values, and variability between repetitions, and process-efficiency parameters, including measurement time and the number of unmeasured points. The proposed approach was experimentally verified using selected measurement system, and selected reference surface. Within this experimental scope, the methodology identified the configuration with Wp = 100.0, fvx = 0.5 μm, fvy = 1.5 μm, and Vf = 190 μm/s, as providing the most favourable balance between surface-roughness characteristics, measurement completeness, and measurement time. Alternative configurations prioritising reduced measurement duration were also evaluated, demonstrating the applicability of the MUZ-based procedure to analysing trade-offs between measurement quality and process efficiency. Based on the experimental results, practical recommendations are formulated for the selection of measurement technologies and optical sensors, taking into account resolution, acquisition time, and implementation costs. The results demonstrate the usefulness of the proposed MUZ-based procedure for the assessment and optimisation of measurement-process parameters within the investigated experimental system. Rather than claiming universal applicability, the study establishes a structured and potentially transferable framework for measurement-system validation and process-parameter optimisation. Its applicability to different reference surfaces, sensors, measurement systems, and manufacturing conditions requires further experimental verification.
No takes yet. Share an insight, caveat, or question.
Bachtiak-Radka et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: