Answers are grounded in this paper and cite their sources.
Background/Objectives: Conventional manually bent titanium plates remain the standard for fixation in orthognathic surgery, whereas patient-specific implants (PSIs), additively manufactured plates, or stock plates pre-bent on a printed model, usually delivered within a guide-based, splintless workflow, aim to eliminate intraoperative plate adaptation and improve transfer of the virtual plan. This systematic review and meta-analysis compared PSIs with conventional plates for three-dimensional (3D) accuracy, skeletal stability, operative efficiency, and complications. Methods: PubMed, Embase, CENTRAL, Scopus, Web of Science, LILACS, and grey literature were searched from inception to 28 August 2026 for randomized controlled trials (RCTs) and non-randomized studies of interventions (NRSIs). Data were pooled with random-effects models (restricted maximum likelihood with Hartung–Knapp–Sidik–Jonkman adjustment). Risk of bias was assessed with RoB 2 and ROBINS-I, and certainty with GRADE. The protocol was submitted to PROSPERO. Results: Thirty-three studies (10 RCTs, 23 NRSIs) were included. All poolable accuracy data came from additively manufactured PSIs. PSIs probably reduce global 3D positional deviation (MD −0.50 mm; 95% CI −0.69 to −0.31; p = 0.0006; moderate certainty), a sub-millimeter difference below accepted clinical thresholds, and may improve pooled accuracy (SMD −0.71; 95% CI −0.95 to −0.47; low certainty), with smaller anteroposterior and yaw errors (very low and low certainty, respectively). Mean skeletal relapse at the longest follow-up did not differ (very low certainty). A single non-randomized cohort of patients with cleft lip and palate (n = 63) reported less relapse ≥ 1 mm at one year with PSIs (horizontal RR 0.09; vertical RR 0.07; very low certainty); this finding cannot be generalized to non-cleft patients. One cohort reported fewer dental root injuries with PSIs (RR 0.06; very low certainty); infection and wound complications did not differ (RR 0.74; 95% CI 0.37 to 1.47; very low certainty). Operative-time results were inconsistent across three small studies (I2 = 95%), and no reliable summary estimate could be derived. A higher hardware-removal rate was observed in the PSI arm of one era-confounded cohort (RR 2.13), which cannot be interpreted as causal evidence of a higher intrinsic removal risk. Conclusions: Additively manufactured PSIs probably improve 3D accuracy by about half a millimeter, a statistically significant but sub-millimeter gain that does not by itself establish a patient-centered benefit for routine cases. Possible reductions in clinically relevant relapse and dental root injury each rest on a single study of very low certainty and require confirmation. These uncertain benefits must be weighed against cost, preoperative lead time, and an evidence base of predominantly low to very low certainty in which several included comparisons tested an entire guide-based splintless workflow rather than the plate alone.
No takes yet. Share an insight, caveat, or question.
Derbishi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: