Answers are grounded in this paper and cite their sources.
Field monitoring of thermal uniformity during Hot Mix Asphalt (HMA) laydown and compaction is critical for preventing premature pavement distress. This study evaluates Unmanned Aerial Vehicles (UAVs) equipped with infrared thermography as a non-destructive tool for monitoring thermal uniformity and cooling dynamics in HMA. A monitoring campaign was conducted in Pulpi, Spain, using a DJI Matrice 600 Pro and a Wiris Pro thermal camera. A total of 11 UAV flights were conducted over a 135 min campaign, yielding 10 post-paving 32-bit radiometric thermal orthomosaics (1.8 cm/pixel GSD) covering a 115 min active cooling sequence and showing high correlation with in situ measurements (R2 ≈ 0.99). Spatial analysis revealed that while the Differential Range Statistic (DRS) indicated severe thermal segregation with overall temperature differences reaching 37 °C, full-surface histogram distributions confirmed that 87% of the mat remained safely within the active compaction window (120–140 °C). Notably, the centerline exhibited higher cooling rates and faster thermal decay than the edges (k¯center≈0.0240 ± 0.0051 min−1, k¯left≈0.0152 ±0.0024 min−1 and k¯right≈0.0211 ±0.0048 min−1), challenging conventional assumptions. This UAV-based approach, integrated with GIS, provides high-resolution mapping that surpasses traditional spot measurements, offering a safer, cost-effective alternative for optimizing compaction windows and ensuring pavement durability.
No takes yet. Share an insight, caveat, or question.
Martínez-Carricondo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: