Answers are grounded in this paper and cite their sources.
Liquefied petroleum gas is used for cooking in most Indian homes and in hotels, hostels, and small industries, and piped natural gas is spreading in many cities. A leak from a worn hose, a loose regulator, or a burner left open can fill a kitchen with gas within minutes, and a single spark from a switch or appliance can then cause a fire or explosion. Many such accidents happen when nobody is present or when the smell is not noticed in time. This paper presents an IoT based gas leakage detection and alert system that senses leaking gas, raises local alarms, takes automatic safety action, and informs the user and neighbours remotely. The system uses an MQ-6 semiconductor gas sensor for LPG together with an MQ-2 sensor for general combustible gases and smoke. Both sensors contain a small heater that keeps the sensing element at its working temperature, and the change in their resistance in the presence of gas is converted into a voltage through a load resistor and read by the analog input of an ESP32 microcontroller. The readings are converted into approximate concentration in parts per million using calibration curves, and a DHT11 sensor provides temperature and humidity so that the effect of these conditions on the sensor can be taken into account. When the gas concentration crosses a warning level, the controller sounds a buzzer and flashes a warning light. If it crosses a higher danger level, the system switches on an exhaust fan through a relay to ventilate the room, closes a 12 V normally open solenoid valve on the gas line, and disconnects the power to non-essential kitchen sockets through a contactor so that no new spark can be produced. These actions are carried out locally and do not depend on the internet connection. At the same time, an alert is sent to the owner through a mobile notification from a cloud platform and through an SMS and a missed call from a SIM800L GSM module. The cloud dashboard shows the live gas level, the state of the fan and valve, and a history of past events. Because a gas sensor must be heated continuously, the power supply was designed with a 12 V adapter, separate regulated rails for the heater, logic, and valve, and a battery backup that keeps the detector working during power cuts. A prototype was tested with controlled release of LPG from a lighter in a closed test chamber. The system detected leaks at about 300 ppm, well below the lower explosive limit of LPG, activated the fan and valve within 2 s of the danger threshold, and delivered the mobile alert in about 6 s. Future work includes wireless detector nodes for several rooms, automatic cylinder weight monitoring, and pattern analysis to distinguish slow leaks from cooking fumes.
No takes yet. Share an insight, caveat, or question.
Sowmya et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: