Answers are grounded in this paper and cite their sources.
Background: Radiation therapy after breast-conserving surgery reduces local recurrence. Three-dimensional conformal radiotherapy (3D-CRT) is widely used, although large setup errors may compromise treatment reproducibility. Frequent image guidance improves setup verification but increases imaging exposure. This study developed a statistical framework to assess setup deviations and inform image-guidance frequency. Methods: Couch coordinates from 35 patients (596 treatment fractions) receiving postoperative whole-breast radiotherapy were retrospectively analyzed. Absolute Z-coordinate deviations from the mean couch position of the first three fractions were calculated, and correlations with image-guidance corrections were assessed. Statistical thresholds were derived from cumulative distributions. Results: A positive correlation was observed between couch-coordinate deviations and image-guidance corrections (Spearman’s ρ = 0.75, p < 0.05). The 95th and 99th percentile statistical thresholds for the absolute Z-coordinate deviation were 4.8 mm and 6.3 mm, respectively. Retrospective application of the proposed flowchart identified 45 fractions exceeding the P95 threshold, including 36 fractions with consecutive threshold exceedances suggesting potential systematic setup deviations. Of 596 fractions, 81 met the framework’s predefined criteria for image guidance. Of 183 fractions actually imaged, 81 met these criteria and 102 did not. This classification does not establish that those sessions could safely or appropriately have been omitted. Hypothetically omitting these 102 fractions from imaging would correspond to an estimated exposure difference of 58–145 mGy per patient, depending on protocol; this was not directly measured. Conclusion: The proposed framework provides a quantitative method for evaluating setup deviations using routinely available couch-coordinate information. Patient-level bootstrap resampling demonstrated statistical stability of the thresholds within this dataset. However, the thresholds have not been calibrated against clinically meaningful geometric or dosimetric endpoints, and the safety of deferring image guidance remains unestablished. External validation and prospective assessment of treatment accuracy, dosimetric impact, and clinical outcomes are needed before implementation.
No takes yet. Share an insight, caveat, or question.
Tsuno et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: