Answers are grounded in this paper and cite their sources.
Post space preparation may induce stress concentration within root dentin and increase the risk of dentinal defects or root fracture after endodontic treatment. Drill geometric design is considered a potential factor influencing the biomechanical behavior during post space preparation; however, the effects of different drill designs on root stress distribution remain unclear. Therefore, this study aimed to evaluate the influence of different post space preparation drill designs on root stress distribution using finite element analysis. A mandibular first premolar finite element model was developed to evaluate five drill configurations, including commercial RelyX Fiber Post Drills (#1 and #2; 3 M ESPE) as the control and four modified designs generated by altering the pitch (one-half [A-type] or one-third [B-type]) and the number of cutting edges (four [C-type] or six [D-type]). Explicit dynamic analysis simulated a two-stage drilling procedure. The magnitude and spatial distribution of the maximum principal stress (σ_max), as well as the cumulative stress exposure quantified by the area under the stress-time curve (AUC), were evaluated. Drill geometry markedly influenced mechanical responses. The B-type drill consistently demonstrated the lowest peak σ_max and combined two-stage AUC. Conversely, the D-type drill produced the highest peak and cumulative stresses. Notably, certain geometric modifications resulted in peak stress concentrations in the apical third, whereas other configurations predominantly exhibited peak stress concentrations in the middle third. Within the limitations of this finite element analysis, drill geometry influenced stress magnitude, distribution, and cumulative exposure within root dentin during post space preparation. The B-type drill exhibited the lowest peak stress in both preparation stages and the lowest combined two-stage AUC, indicating a relatively favorable stress profile under the simulated conditions. The findings indicate that drill geometric parameters, particularly pitch and cutting edge number, influence stress distribution patterns during post space preparation. A reduced pitch design with a moderate number of cutting edges showed a relatively lower stress response under the simulated conditions. These findings provide comparative biomechanical insights into the effects of drill geometry and may inform future investigations of post space preparation instrument design.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: