Answers are grounded in this paper and cite their sources.
The effect of MHD instabilities on runaway electron (RE) avalanche and termination in ITER mitigated disruptions is investigated using MHD simulations with the JOREK code. 3D simulations show that the MHD stability during the current quench (CQ) is highly sensitive to the density profile and the initial current profile after the thermal quench. The impurity and electron density distributions play a dominant role by influencing the temperature and current-density profiles during the CQ. In the most unstable simulation case with high edge density and sufficient edge cooling, magnetic field lines stay globally stochastic for more than 10 ms, substantially reducing the peak RE current to kA level in the baseline simulation. To assess uncertainty in the diffusion-based fluid RE transport model, the parallel diffusivity is reduced from 10 10 to 10 9 m 2 s -1 in a reference case, giving an upper-limit estimate of 0.57 MA for the peak RE current. Due to limited diagnostic data during disruptions, the link between the current profile and CQ MHD activity has not been tested on a present-day machine. In cases with a multi-MA-scale saturated RE current, RE termination is found to be a slow process induced by plasma vertical motion and edge stochasticity, rather than a rapid collapse driven by intense global MHD instabilities. Such slow termination converts a substantial fraction of the magnetic energy into RE kinetic energy, increasing potential damage to the first wall.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: