Key result
Zero-fluoroscopy transcatheter closure under TEE guidance successfully closes large ASD with a single device.
Why the study?
Percutaneous transcatheter closure in patients with multiple secundum ASDs remains a significant challenge, with considerable debate about whether a single device is sufficient or multiple devices are needed when defects are not close to each other.
Case Report (n=1)
Demonstrates the feasibility of zero-fluoroscopy, TEE-guided percutaneous transcatheter closure of a large secundum ASD in a patient with multiple defects using a single device after careful anatomic and hemodynamic assessment.
Answers are grounded in this paper and cite their sources.
Supports feasibility of zero-fluoroscopy TEE-guided single-device closure for multiple secundum ASDs; hypothesis-generating and leaves open broader applicability.
Background: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases. Percutaneous transcatheter closure (PTC) has become an alternative to surgery, especially in cases of secundum ASD. PTC in patients with secundum ASD with specific deficiencies, such as multiple rim deficiencies and multiple defects, remains a significant challenge. There is still considerable debate about whether a single device is sufficient to close two or more defects, or whether two or more devices are needed if the defects are not close to each other. Case presentation: This case is a 41-year-old woman with multiple secundum ASDs and adequate rims where the large ASD (1st ASD) was successfully closed with a Lifetech Cera device with zero fluoroscopy, the insertion of which was guided by transesophageal echocardiography (TEE) and still left a small defect (2nd ASD) with several considerations. Conclusion: A thorough assessment of the anatomy and hemodynamics of patients with multiple secundum ASDs is crucial. Closure of multiple secundum ASD defects using PTC depends on several factors, including the presence or absence of pulmonary hypertension, the number of defects, and their size. These factors can influence the decision to close multiple defects and are also crucial in selecting the appropriate device based on the size of the defect to be closed.
No takes yet. Share an insight, caveat, or question.
Sutarmini et al. (2026) conducted a case report in Multiple secundum atrial septal defects (ASDs) (n=1). Percutaneous transcatheter closure (PTC) with a Lifetech Cera device under zero fluoroscopy guided by transesophageal echocardiography (TEE) was evaluated on Closure of the large secundum atrial septal defect. Percutaneous transcatheter closure using a single Lifetech Cera device under TEE guidance with zero fluoroscopy successfully closed the large ASD while leaving a small secondary defect.
Synapse has enriched 10 related papers. Consider them for comparative context: