Key result
Totally endoscopic AVR for quadricuspid aortic valve achieves normal function with ~14 mmHg mean gradient.
Why the study?
Quadricuspid aortic valve commonly presents with progressive aortic regurgitation requiring surgical replacement, but whether this anatomy can be safely addressed via a totally endoscopic approach had not been demonstrated in detail.
Case Report (n=1)
No
Demonstrates a reproducible step-by-step surgical workflow showing that totally endoscopic aortic valve replacement is feasible and safe for treating severe aortic regurgitation in a patient with a rare quadricuspid aortic valve.
Answers are grounded in this paper and cite their sources.
Extends endoscopic AVR experience to rare quadricuspid anatomy; leaves open generalizability and need for comparative trials.
Quadricuspid aortic valve is a rare congenital anomaly that commonly presents with progressive aortic regurgitation and requires surgical valve replacement. Whether this anatomy can be safely addressed through a totally endoscopic approach has not been demonstrated in detail. We present a 62-year-old man with severe aortic regurgitation due to a Hurwitz–Roberts type A quadricuspid aortic valve who underwent totally endoscopic aortic valve replacement. The procedure was performed through a standardized three-port right thoracotomy with femoral arterial and venous cannulation under vacuum-assisted venous drainage. After transthoracic external aortic cross-clamping, myocardial protection was achieved with blood cardioplegia delivered directly into the coronary ostia, and the four-cusped valve was excised under three-dimensional endoscopic magnification. A 23 mm bovine pericardial bioprosthesis was implanted with 15 everting mattress sutures of coated polyester braid, secured with automated titanium fasteners. The patient was extubated soon after the operation and discharged on postoperative Day 10. Echocardiography at 3.5 months confirmed normal prosthetic function with a mean gradient of 14 mmHg and progressive left ventricular reverse remodelling. This video tutorial illustrates a reproducible step-by-step workflow for totally endoscopic aortic valve replacement applied to quadricuspid aortic valve, and provides practical guidance for surgeons encountering this anatomy.
No takes yet. Share an insight, caveat, or question.
A 2026 study conducted a case report in Severe aortic regurgitation due to a Hurwitz-Roberts type A quadricuspid aortic valve (n=1). Totally endoscopic aortic valve replacement with a 23 mm bovine pericardial bioprosthesis was evaluated on Prosthetic valve function and postoperative recovery at 3.5 months. Totally endoscopic aortic valve replacement for quadricuspid aortic valve achieved normal prosthetic function with a mean gradient of 14 mmHg at 3.5 months.
Synapse has enriched 10 related papers. Consider them for comparative context: