Key result
Transaxillary rapid-deployment aortic valve replacement enables on-table extubation and discharge in 5 days.
Why the study?
Right anterior minithoracotomy provides direct vision of the aortic valve through a less favourable trajectory and a limited anterior intercostal space, whereas a right transaxillary minithoracotomy with a rapid-deployment valve is presented to simplify minimally invasive aortic valve replacement using standard instruments.
Case Report (n=1)
Demonstrates the feasibility of combining a right transaxillary minithoracotomy with a rapid-deployment aortic valve using standard instruments to facilitate fast-track recovery and on-table extubation.
Answers are grounded in this paper and cite their sources.
May support fast-track transaxillary AVR in select patients; hypothesis-generating and requires prospective comparative trials.
We present a minimally invasive aortic valve replacement performed through a right transaxillary minithoracotomy. This approach uses a single 4–5 cm lateral incision, minimizing chest wall trauma while providing excellent cosmetic results. It redefines surgical perspective by offering a direct, non-mediated view of the aortic valve with a naturally perpendicular trajectory to the annular plane. This results in optimal eye–hand alignment, shorter working distance and enhanced operative control, simplifying the procedure, not only compared to endoscopic or robotic techniques, but also to right anterior minithoracotomy, where direct vision is obtained through a less favourable trajectory and a more limited anterior intercostal space. The procedure is performed using standard instruments and standardized set-up, without the need for specialized or expensive technologies, improving reproducibility and scalability. Its intrinsic simplicity makes it particularly suited for fast-track protocols, facilitating on-table extubation and early mobilization. The combination with rapid-deployment valves further streamlines the operation by reducing cardiopulmonary bypass and cross-clamp times, while the transaxillary exposure ensures accurate annular alignment and controlled, symmetrical deployment. In this case, the patient was extubated on-table and discharged home after 5 days, illustrating how this approach can simplify minimally invasive aortic valve surgery while maintaining safety and precision.
No takes yet. Share an insight, caveat, or question.
A 2026 study conducted a case report in Aortic valve disease requiring replacement (n=1). Transaxillary direct-view aortic valve replacement with Intuity Elite rapid-deployment valve was evaluated on On-table extubation and hospital length of stay. Transaxillary direct-view aortic valve replacement with an Intuity Elite rapid-deployment valve through a 4-5 cm incision enabled on-table extubation and hospital discharge after 5 days.
Synapse has enriched 10 related papers. Consider them for comparative context: