Answers are grounded in this paper and cite their sources.
Molecular hydrogen (H2) is released during the atmospheric oxidation of coal but is absent from the index-gas system used for early warning of coal spontaneous combustion (CSC), because conventional temperature-programmed oxidation (TPO) platforms use H2 as the chromatographic carrier gas, which masks the coal-derived signal. We retrofitted a 1 kg-scale CSC-TPO system with a high-purity argon carrier and validated H2 quantification (limit of detection 0.2 × 10−4 vol%; between-run relative standard deviation 4–8%). Four coals from Heilongjiang Province, spanning long-flame to coking rank, were oxidized in air from 30 to 200 °C, with companion runs in N2 and isothermal FTIR characterization of oxidized samples. H2 release was staged in all four coals: below 0.01 vol% up to about 70 °C, a progressive rise to 150 °C, and a steep increase to 0.098–0.194 vol% at 190–200 °C; for this sample set, peak concentrations decreased in the order DR > JD > RH > LH. Under N2, H2 above 100 °C fell below 7% of the air value, indicating that high-temperature release requires molecular oxygen. Hydroxyl and oxygen-containing bands peaked near 50 °C and declined by 150 °C, whereas aliphatic C–H decreased monotonically. The water–gas shift route is not expected to contribute appreciably below 200 °C, whereas radical recombination and decarboxylation remain equally consistent with the data. H2 is proposed as a candidate auxiliary early-warning indicator requiring field validation.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: