Answers are grounded in this paper and cite their sources.
This study evaluates electrically insulating silicone thermal interface materials (TIMs) at the coil-to-ferrite and ferrite-to-shield interfaces of an electric-vehicle wireless charging receiver. A steady-state Maxwell–Icepak model compares TIM conductivity, interface location, and coverage using prescribed winding currents of 15 A peak at 85 kHz and an ambient temperature of 25 °C. For the bare receiver, the predicted coil hotspot is 82.49 °C, which is 2.51 °C below the study’s internal screening reference of 85 °C. With TIM-B at both interfaces and 100% coverage, the predicted hotspot falls to 64.54 °C, a reduction of 17.95 °C. A single TIM-B layer retains 83.7–85.1% of this reduction while using half the TIM volume. At 110% and 120% coverage, the predicted coil hotspots are 59.90 and 60.28 °C. Their 0.38 °C difference does not support a definitive ranking. These results apply to the modeled geometry, thermal boundaries, and fixed-current excitation.
No takes yet. Share an insight, caveat, or question.
Song et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: