Answers are grounded in this paper and cite their sources.
Active vibration control units are crucial for ensuring accuracy in ultra-precision engineering, yet their intensive real-time computational loads generate high heat fluxes that threaten system stability. To address thermal dissipation under severe spatial constraints, this study proposes a multi-level thermal design methodology spanning system-level component matching and cold-plate optimization. A fan–radiator coupled model based on thermodynamic equilibrium was established to quantitatively match fan aerodynamic characteristics with the effective heat-transfer area of the radiator, reducing spatial redundancy under volume constraints. At the component level, an optimized cold plate incorporating a three-stage deflector and discontinuous short fins was developed to alleviate the thermo-hydraulic conflict caused by increasing fin density. Under a 360 W thermal load, the optimized design reduced the overall flow resistance by approximately 2300 Pa to 7409.84 Pa while maintaining effective heat dissipation. These results provide a systematic thermal design approach for high-power active vibration control units under restricted space.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.