Answers are grounded in this paper and cite their sources.
A reinforcement technique using a glass fiber–reinforced polymer (GFRP) bar–ultrahigh-performance concrete (UHPC) precast layer is proposed in this study to overcome the limitations of conventional bridge strengthening methods in simultaneously achieving lightweight construction, high durability, and rapid installation. In this technique, UHPC and GFRP bars are integrated to form a channel-shaped strengthening member, which is externally bonded to the tensile zone of the structure. This configuration effectively reduces the additional self-weight, while significantly enhancing the load-carrying capacity and durability of the strengthened system. Prestressing can be introduced into the GFRP bars to further improve crack resistance and long-term structural performance further. Before strengthening, the substrate surface of the T-beam was chiseled and grooved, after which the strengthening member—featuring internal shear keyways—was bonded to the tensile zone using a high-strength mortar to form a composite system. The flexural behavior and strengthening effectiveness of damaged T-beams strengthened with the proposed GFRP bar–UHPC precast layer were investigated through a four-point bending test. The results indicate that the flexural failure of the strengthened beams was governed by the GFRP bars in the tensile zone. Compared with the unstrengthened T-beam, the strengthened specimens across the investigated strengthening configurations exhibited increases of 176%–191% in ultimate load capacity and 93%–239% in flexural stiffness, while the cracking load of the prestressed specimen increased by 205%. These findings demonstrate the strengthening efficiency of the GFRP bar–UHPC reinforcement layer. Moreover, the composite action of beams strengthened with a cast-in-place UHPC layer was superior to that of precast layers, as evidenced by a 51% reduction in interface slip. Provided that sufficient interfacial roughness is ensured, adequate shear-friction performance can be achieved by directly bonding the channel-shaped strengthening member to the T-beam using a high-strength mortar, thereby eliminating the need for additional dowel bars. Finite-element parametric analyses reveal that increasing the UHPC layer thickness and the prestress level of GFRP bars has a limited effect on flexural strength, whereas increasing the GFRP bar diameter within a reasonable range effectively enhances the flexural capacity. Finally, a method for calculating the flexural bearing capacity of damaged T-beams strengthened with the GFRP bar–UHPC precast layer is proposed.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: