Answers are grounded in this paper and cite their sources.
Floor heave in deep soft-rock roadways is often associated with shear deformation of weak floor strata under high lateral stress. The reinforcement mechanism of inclined anti-shear pipe piles is investigated using a slip-line-field interpretation. An idealized potential shear-slip path is considered near the boundary between the active and transition zones. Pile–slip-path interaction is interpreted through the local intersection geometry and associated axial and transverse deformation responses. Numerical simulations show that combined pipe-pile and ground-improvement reinforcement reduces the maximum displacement magnitude from 146 to 64 mm, representing a reduction of 56.2%. Among seven simulated inclinations, 60° yields the smallest maximum vertical floor displacement of 64 mm under the investigated conditions. Field monitoring at Guqiao Coal Mine recorded cumulative floor heave of 32–45 mm in the section treated with pipe piles, cement grouting and additional floor support measures. These findings provide a mechanical interpretation of inclination-dependent floor restraint and supporting evidence of the practical effectiveness of the combined reinforcement system.
No takes yet. Share an insight, caveat, or question.
kang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: