Independent boarding by persons with reduced mobility (PRM) at tram stops requires the waiting position to coincide with the stopping position of the accessible tram doors. This link has rarely been examined. This study assesses PRM waiting areas and manoeuvring space against an integrated standard combining Polish national design guidelines and the local requirements of Wrocław, with the manoeuvring space derived from the door positions of the seven accessible tram models in the fleet. Five criteria (dimensions, location and marking of the waiting area, manoeuvring space and platform edge height) were assessed using the Levels of Compliance with Requirements (LOR) method at 96 stops with direct platforms. No stop met all requirements; the mean LOR value was 0.37. A waiting area was present at 44.8% of the stops; 95.3% of these lay within the manoeuvring space, but only two were at the required position relative to the assumed stopping point. Edge height and manoeuvring space requirements were met considerably better than waiting-area requirements. The national and local requirements proved compatible, and the main gap concerns marking rather than platform geometry. The procedure can be applied to other tram networks once their local requirements and rolling stock are taken into account.