Answers are grounded in this paper and cite their sources.
Rail transit stray current causes severe corrosion and endangers the safe operation of buried steel pipelines. Based on field-monitored interference signals, three stray current modes are designed: steady-state direct current (SDC, +5 mA ⋅ cm −2 ), symmetric bipolar dynamic direct current (SDDC, ±5 mA ⋅ cm −2 ), and asymmetric bipolar dynamic direct current (ADDC, +2.5/−5 mA ⋅ cm −2 ). Eight-day soil corrosion tests combine weight loss, polarization curves, electrochemical impedance spectroscopy, level set simulation, and three-dimensional laser scanning to investigate steel corrosion and pitting behaviors. Results show that Q235B steel remains continuously active under SDC and SDDC, while ADDC triggers incomplete passive film formation. SDC-driven corrosion is charge transfer controlled and forms deep pits with a maximum depth of 864.4 μ m after 8 days. For SDDC, the dominant corrosion mechanism evolves from mass transfer to corrosion film impedance control, and discrete pits coalesce into flat, uniform corroded zones peaking at 115.6 μ m depth. Localized micro-pits form on specimens under ADDC, with a maximum depth of 54 μ m. Pit depth grows linearly over corrosion duration, and pit propagation rates under steady DC interference greatly exceed those under dynamic DC waveforms. This study provides references for anticorrosion design and service life prediction of urban buried steel pipelines suffering rail transit stray current.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: