A two-way CFD–DEM calculation of the first 180 s of wheat drying in a narrow fluidized bed was examined using five-sphere rigid grains and an empirical, effective-diffusivity-based particle-average drying law. Nine nominal inlet cases (80, 100 and 120 °C; 3.0, 3.3 and 3.6 m s⁻¹) were reported. A separate literature-curve feasibility comparison (Fig. 4) used an initial moisture content of 30% dry basis, an inlet velocity of 3.3 m s⁻¹ and an inlet temperature of 373.15 K; it is not one of the nine 25%-dry-basis simulations. The 80 and 100 °C results describe model-conditioned early heating and moisture-loss trends; the 120 °C drying histories are affected by a numerical |dM/dt| ceiling of 8.0 × 10⁻⁴ s⁻¹ and cannot establish uncapped kinetics. The sensitivity and consistency analyses in Sections 2.4.2–2.4.3 address effective diffusivity, internal diffusion resistance, particle-side mass and energy exchange, the empirical heat-transfer correction factor, and the drying-rate ceiling. These analyses are diagnostics, not new fully coupled CFD–DEM runs. The available evidence supports comparative model behavior but does not establish grid convergence, solver-wide conservation, or independent predictive validation.