Answers are grounded in this paper and cite their sources.
Objectives To evaluate diagnostic performance, radiation dose, and quantitative spectral characteristics of dual-phase photon-counting CT (PCD-CT) for parathyroid adenoma localization after inconclusive first-line imaging. Materials and methods Consecutive patients with primary hyperparathyroidism and negative, discordant, or inconclusive first-line imaging underwent paired [ 18 F]FECh PET/CT and dual-phase PCD-CT with arterial and venous acquisitions. Three radiologists, blinded to clinical and reference-standard information, retrospectively assessed arterial and portal-venous 40- and 70-keV images and VNC reconstructions. The reference standard comprised surgery/histopathology with biochemical confirmation, concordant PET/CT with persistent biochemical disease in nonsurgical positive patients, or clinical/biochemical resolution in negative patients. Lesion-level sensitivity, positive predictive value (PPV), and interreader intraclass correlation (ICC) were calculated. Aorta-normalized attenuation and wash-in and wash-out metrics were compared among adenomas, thyroid tissue, and lymph nodes. Results Forty-nine patients (mean age, 64.2 ± 10.9 years; 42 women) were included, with 45 patients having 49 reference-standard-positive lesions. PCD-CT lesion-level sensitivity was 67.3%–83.7%, and PPV 67.3%–90.0%, with an interreader agreement of 0.506. Aorta-adjusted wash-out was greater in adenomas (27.2%) than in thyroid (20.2%) and lymph nodes (−3.1%; both p < 0.001). Arterial adenoma–thyroid attenuation and wash-in overlapped between adenomas did not differ significantly (arterial p = 0.615 and thyroid tissue. 0.945 at 40 and 70 keV; wash-in p = 0.363). Mean estimated effective dose was 1.23 ± 0.47 mSv. Conclusion Dual-phase PCD-CT provided reader-dependent parathyroid localization at low radiation dose in a difficult second-line cohort. Quantitative wash-out may aid differentiation from thyroid and lymph-node mimics but requires prospective threshold validation. Key Points Question Inconclusive first-line imaging complicates parathyroid lesion localization. Findings Reader sensitivity ranged from 67.3% to 83.7% at 1.23 mSv. Critical relevance statement Aorta-adjusted wash-out differed among parathyroid lesions, thyroid tissue, and lymph nodes.
No takes yet. Share an insight, caveat, or question.
Rau et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: