Key result
Abnormal Cardisiography p-factor linked to ~22-point higher angiographic CAD score.
Why the study?
Whether the output of cardisiography, an AI-enhanced vectorcardiographic system reporting composite perfusion and structural indices, is associated with the angiographic severity of CAD had not been directly tested.
Does AI-enhanced vectorcardiography (Cardisiography) correlate with angiographic coronary artery disease burden (GENSINI score) in patients referred for invasive coronary angiography?
Observational (n=103)
No
Does AI-enhanced vectorcardiography (Cardisiography) correlate with angiographic coronary artery disease burden (GENSINI score) in patients referred for invasive coronary angiography?
AI-enhanced vectorcardiographic perfusion indices (Cardisiography p-factor) show a statistically significant graded association with angiographic coronary artery disease burden (GENSINI score), but demonstrate only modest diagnostic accuracy (AUC 0.58–0.68).
Answers are grounded in this paper and cite their sources.
Abnormal p-factor was associated with higher Gensini scores; hypothesis-generating for Cardisiography, prospective validation required before clinical consideration.
Background: Cardisiography (CSG) is an AI-enhanced vectorcardiographic (VCG) system that reports composite perfusion (p-factor) and structural (s-factor) indices from a short resting recording. Whether CSG output is associated with the angiographic severity of coronary artery disease (CAD) has not been directly tested. Methods: We retrospectively analysed 103 consecutive patients referred for invasive coronary angiography at a single tertiary centre. The extent and severity of coronary artery disease were quantified with the GENSINI score. GENSINI scores were compared between patients with a normal (p-factor 0–1) and an abnormal (p-factor 2–3) CSG p-factor, and across the four ordinal p-factor categories; continuous VCG parameters were correlated with GENSINI on the continuous scale. A composite (p + s) index was examined as an exploratory analysis. Diagnostic accuracy for angiographic CAD was assessed at three severity thresholds (GENSINI > 0, ≥20 and ≥40). Results: Mean age was 57.5 ± 12.7 years and 72% were men. Patients with an abnormal p-factor had a higher GENSINI score than those with a normal p-factor (73.2 ± 51.2 vs. 50.9 ± 46.9; p = 0.034). A graded association between p-factor category and GENSINI burden was supported by a formal trend test (p = 0.007). QRS–T angle, T vector, superposition, p-index and T-wave scatter changed progressively across p-factor categories (all p < 0.001, retained after false-discovery-rate correction). AUCs for angiographic CAD were modest (0.58–0.68). The composite (p + s) > 3 was not associated with GENSINI (p = 0.096). Conclusions: CSG-derived VCG indices were associated with angiographic CAD burden; AUCs were modest. Larger prospective studies are needed to confirm these findings before clinical application.
No takes yet. Share an insight, caveat, or question.
Guctekin et al. (2026) conducted an observational in Coronary artery disease (n=103). Abnormal Cardisiography p-factor (2-3) vs. Normal Cardisiography p-factor (0-1) was evaluated on Angiographic coronary artery disease severity quantified by GENSINI score (p=0.034). Abnormal Cardisiography p-factor was associated with higher angiographic CAD burden than normal p-factor, with modest AUCs.
Synapse has enriched 10 related papers. Consider them for comparative context: