BACKGROUND: The transport and storage conditions of thawed plasma are not strictly regulated by the regulatory bodies and applying the red blood cell transport standard of 1-10°C to recently thawed plasma often results in high discard rates. This study evaluated the extended 120-h (5-day) coagulation factor stability and sterility of thawed plasma frozen within 24 h after collection (PF24) following a 6-h transport cooler simulation. STUDY DESIGN AND METHODS: Fourteen PF24 units (8 group O, 6 group B) were thawed at 30-37°C and assigned as control (n = 7, direct 1-6°C refrigeration) or experiment (n = 7) units. Experiment units were held at room temperature for 30 min, stored in validated transport coolers for 6 h, and then transferred to 1-6°C refrigeration. Measurements of temperature, prothrombin time (PT), Factor V (FV) activity, and Factor VIII (FVIII) activity were conducted at 0-, 6-, 24-, and 120-h post-thaw. Sterility testing was performed at 0- and 120-h using automated aerobic and anaerobic blood cultures. RESULTS: ) confirmed equivalent factor decay rates between groups. All bacterial cultures showed no growth at 120-h. CONCLUSION: A 6-h cooler time of thawed PF24 does not accelerate coagulation factor degradation or compromise sterility over an extended 5-day shelf life. These findings validate flexible inventory return policies, allowing blood banks to reduce product waste.