Answers are grounded in this paper and cite their sources.
This study experimentally investigates the overall isentropic efficiency of a small hermetic reciprocating compressor (1.75 cm³/rev) operating in a transcritical CO₂ heat pump under warm climate conditions and develops predictive correlations tailored to the investigated compressor. A total of 245 steady-state operating points, covering pressure ratios between 1.2 and 2.6, were obtained from a controlled experimental campaign. Conventional polynomial correlations based exclusively on the pressure ratio were initially developed and statistically evaluated, yielding coefficients of determination greater than 0.95. However, increased experimental data dispersion was observed at pressure ratios above approximately 2.0, which may be associated with the combined effects of elevated discharge temperatures, increased compression irreversibilities, and the strong thermophysical sensitivity of CO₂ in the transcritical region. To improve the predictive capability of the pressure-ratio-based models, a multivariable dimensionless correlation was developed for the investigated compressor, incorporating the pressure ratio, compressor volumetric efficiency, reduced temperatures, and gas cooler heat capacity ratio. The proposed model achieved an adjusted coefficient of determination of 0.989 and reduced the mean absolute relative deviation (MARD) of overall isentropic efficiency predictions to 4.29%, outperforming the conventional correlations based exclusively on pressure ratio within the investigated experimental domain. The experimental results further revealed an increasing trend in the overall isentropic efficiency throughout the investigated pressure ratio range, without identifying a maximum efficiency condition. This finding highlights the importance of considering the thermal operating limitations of the investigated compressor, particularly under warm climate conditions, where increasing discharge temperatures may restrict the accessible operating range before a maximum efficiency condition can be experimentally identified. Furthermore, integrating the proposed correlation into the heat pump thermodynamic model improved the prediction of the experimental coefficient of performance (COP), yielding a global MARD of 2.52% across the investigated operating conditions. An additional independent experimental assessment under representative warm climate conditions resulted in absolute relative deviations of 1.60% for overall isentropic efficiency and 1.16% for COP. Overall, the results demonstrate the importance of incorporating dimensionless parameters associated with the thermal and volumetric operating conditions when predicting the overall isentropic efficiency of the investigated small-capacity compressor. The proposed formulation provides an improved predictive representation within the experimentally investigated domain and can support the thermodynamic modeling of small-capacity transcritical CO₂ heat pumps operating under similar conditions, particularly in warm climate applications. Further investigations involving compressors with different displacement volumes, designs, and operating conditions are required to assess the broader applicability of the proposed correlation.
No takes yet. Share an insight, caveat, or question.
Silva et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: