Answers are grounded in this paper and cite their sources.
Geothermal energy represents a promising renewable resource for sustainable energy production due to its continuous availability. Among various configurations, closed-loop geothermal systems are gaining traction for their operational flexibility and minimal environmental footprint. This paper presents the development and validation of a quasi-steady model for simulating the thermofluid-dynamic behavior of a closed-loop geothermal well operating with pure CO 2 and CO 2 -based mixtures. The model tracks fluid property evolution along the well by solving the conservation equations of mass, momentum, and energy, while coupling heat exchange with the surrounding ground. To handle complex mixture thermodynamics efficiently, a Property Table-based approach is adopted, ensuring high accuracy while significantly reducing computational cost compared to conventional flash calculations, achieving a 95% reduction in runtime. A parametric analysis demonstrates that CO 2 -based mixtures consistently perform better than pure CO 2 in both extracted heat and outlet pressure. Moreover, for geothermal gradients exceeding 0.06 °C/m in the studied case, the Levelized Cost of Heat (LCOH) is minimized at a horizontal extension of 500 m, whereas the Levelized Cost of Energy (LCOE) plateaus and remains nearly constant after 1000 m. Ultimately, these findings highlight the potential of engineered mixtures to enhance closed-loop geothermal performance, offering a computationally efficient tool for designing advanced operating configurations.
No takes yet. Share an insight, caveat, or question.
Falchini et al. (2026) studied this question.