Answers are grounded in this paper and cite their sources.
Thermally induced line-of-sight instability under wide-temperature-range thermal loads (20 ± 10 °C) is a critical challenge for space cameras. This paper presents a passive athermal flexure mount for a 360 mm aperture camera via an opto-mechanical-thermal integration framework. Optical sensitivity analysis identifies the primary mirror as the key optical element, guiding the flexure structural optimization. Thermo-structural-optical simulations over the same temperature range yield a maximum LOS drift of 0.0484″/°C and surface figure RMS better than λ/30. Radial gravity yields a surface figure better than λ/50. Dynamic vibration tests confirm a first natural frequency of 183.82 Hz with deviation <5%, validating the passive athermal design for wide-temperature-range athermalization.
No takes yet. Share an insight, caveat, or question.
Ma et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: