Answers are grounded in this paper and cite their sources.
To address the difficulty of achieving dynamic coordination between particulate removal efficiency and energy consumption under wide load fluctuations, this study develops digital twins (DTs) system for an electrostatic precipitator (ESP) based on a three-layer architecture comprising geometric modeling, multiphysics coupled modeling, and data-driven correction. The proposed DT system characterizes the coupled dynamic behavior of the electric field, flow field, temperature field, and particle motion field. An online parameter identification scheme based on recursive least squares is then integrated to establish a time-varying discrete state-space model. Based on this model, an adaptive model predictive control (MPC) strategy is developed, and a constrained multi-objective optimization problem is formulated to achieve coordinated optimization of particulate removal efficiency and energy consumption. The proposed framework is validated using publicly available operational data from two 350 MW units equipped with ESPs. The results show that the coefficients of determination (R²) for flue gas temperature, secondary voltage, and outlet opacity are all greater than 0.985. After dividing the data into training and testing sets, the out-of-sample evaluation demonstrates that the DT model can effectively reproduce the dynamic behavior of the ESP under wide load disturbances. Compared with conventional proportional-integral-derivative (PID) control, the proposed adaptive MPC increases the average particulate removal efficiency by 2.5% and reduces energy consumption by 8.9%. The amplitudes of voltage and current fluctuations decrease by 57.4% and 60.0%, respectively, while the settling time is reduced by 44.7% and the overshoot is reduced by 66.7%. Under load fluctuations of ± 30%, the average particulate removal efficiency reaches 96.8%, with its standard deviation reduced by 52.0%. Statistical evaluation indicates that a P-value of < 0.001 alone is insufficient to establish model accuracy; instead, out-of-sample error metrics provide direct evidence of predictive performance. The results demonstrate that the proposed DT system can capture the dynamic operating characteristics of the ESP, while the adaptive MPC effectively suppresses disturbances caused by operating-condition fluctuations and achieves multi-objective coordinated optimization. This study addresses the limitations of conventional ESP control strategies that rely primarily on steady-state models and provides a practical methodological framework for intelligent operation and maintenance of industrial ESPs under wide load fluctuations.
No takes yet. Share an insight, caveat, or question.
Yachao Li (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: