Answers are grounded in this paper and cite their sources.
Random packed bed thermal energy storage (PBTES) systems using phase change material (PCM) capsules often suffer from flow maldistribution and low thermal stratification, which limit charging efficiency. Structured arrangements such as grille-capsule composite packed bed thermal energy storage (CPBTES) systems are able to direct flow and improve heat transfer. In this work, a grille-capsule CPBTES system with PCM capsules is established and compared with a random PBTES (RPBTES) system. The charge performance of the CPBTES system under different heat transfer fluid (HTF) flow rates and capsule diameters is investigated experimentally. Results show that the grille increases the pressure drop by nearly 20% but enhances heat transfer, leading to a higher stratification number. A distinctive oscillatory evolution of the stratification number is observed and attributed to the interplay between structured flow and isothermal phase change. The energy efficiency of the CPBTES system reaches 88.94% compared to 76.79% for the RPBTES system at an HTF flow rate of 0.4 L/min. The exergy efficiencies are 68.04% and 60.96%, respectively. Increasing the HTF flow rate accelerates charging but reduces exergy efficiency from 70.10% to 65.77%. Capsule diameter has no significant impact on the stratification number, energy efficiency, or exergy efficiency. This study provides insights into the coupling of structured flow and latent heat storage for compact high-performance systems.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: