Answers are grounded in this paper and cite their sources.
Background: Input resolution is usually reported as apreprocessing setting in retinal lesion segmentation, yet downsamplingcompresses small lesion annotations far more than large ones. We asked howresolution, encoder family and decoder design jointly affect segmentation ofmicroaneurysms, haemorrhages, hard exudates and soft exudates, and how much ofan apparent architecture ranking survives testing. Because input size alsochanges token count, positional-embedding interpolation, window configurationand the memory plan, we estimate resolution-conditioned system performance, notan isolated effect of spatial resolution. Methods: Four ImageNet-pretrained Transformer systems (ViT-Small/16,CaiT-XS24, Swin-Tiny, SwinV2-CR-Tiny) were trained on the FGADR Seg-set at 224,384, 512 and 768 pixels with five seeds each, under one frozen image-disjointpartition, schedule and scoring pipeline. A shared-final-decoder control and afixed-budget GroupNorm U-Net reference completed a frozen base of 120 models,evaluated on a held-out FGADR cohort and by zero-shot transfer to IDRiD.Outcomes were pooled pixel-level AUPR and mean average precision overlesion-positive images. Systems were compared under seed-paired \((t)\)-tests and ahierarchical seed-and-image bootstrap with Holm correction, and by equivalencetesting at margins of 0.01, 0.02 and 0.03. Results: Between 224 and 768 pixels macro pooled AUPR rose for all foursystems on FGADR (0.0794--0.1614) and IDRiD (0.1198--0.2150), but notmonotonically: CaiT-XS24 peaked at 512 pixels, a decline absent on FGADR underpositive-image aggregation. Most multiplicity-adjusted evidence lay in the firststep of the range. Pairwise testing separated systems far more readily underevaluation-cohort than seed resampling; externally at 768 pixels the two agreedon none of ten pairs. The hierarchical systems were equivalent internally at512 pixels and above at margins of 0.02 and 0.03, but not 0.01. A shared decoderreversed the ViT-Small/16 versus SwinV2-CR-Tiny ordering in all four conditions(\((pHolm=0.004)\)), an encoder--decoder interaction. Macro calibrationerror fell in all eight Transformer conditions (sign test \((p=0.008)\)), andtraining cost per epoch rose 11- to 38-fold. Conclusions: The benefit of resolution is neither universal, nordecoder-independent, nor free, and part of it depends on how performance isaggregated over lesion-negative images. Resolution, encoder and decoder shouldbe chosen together and reported with calibration, aggregation and measuredcompute.
No takes yet. Share an insight, caveat, or question.
Adekunle et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: