Answers are grounded in this paper and cite their sources.
This paper presents an experimental study of the melting characteristics of a PCM rectangular thermal storage system. The LHESS is composed of a shell and tubes with circulating heat transfer fluid (HTF; water in this study). Stearic acid is used as the PCM and placed in the space between the shell and tubes. The melting process of the phase change material is investigated with flow rate and inlet temperature parameters. According to the experimental results, as the inlet temperature was increased by 65°C, 75°C, and 80°C, the melting time was 51%, 64.46%, and 73.28%, respectively, for a fluid flow rate of 4.61 l/min. Moreover, the results showed that the effect of HTF flow on the thermal energy storage (TES) is 9%, 10%, and 15% for the flow rates of 4.61 l/min, 4.61 l/min, and 1 l. / min, respectively.
No takes yet. Share an insight, caveat, or question.
Djefel et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: