Answers are grounded in this paper and cite their sources.
Armored vehicles in severe environments should satisfy thermal comfort requirements under constrained cooling capacity and weight budgets. Although three-dimensional (3D) conjugate heat transfer (CHT) simulations provide higher fidelity, their high computational cost limits practical use in iterative optimization and parameter study. To address this, a one-dimensional (1D) thermal model calibrated against 3D CHT simulations is applied to two engineering problems. First, the wall-specific insulation thickness is optimized to minimize total mass, while all walls are thermally coupled through the cabin. The optimized design reduces the insulation mass by 41.6% relative to a uniform 30 mm design and by 17.1% relative to the optimal uniform design. Furthermore, a design curve is presented for the required mass to satisfy the target temperature for different evaporator capacities, from which the minimum required capacity is determined to be in the range of 7.75 and 8.0 kW. Second, the air gaps in multi-layered hulls, difficult to measure on assembled vehicles, are represented by an effective air gap and estimated from the full-scale experiment. When applied to the 3D model, the estimated effective air gap of 3 mm reproduces the experimental data in the soak and cool-down phases with root-mean-square errors (RMSE) of 0.46 °C and 0.66 °C, respectively.
No takes yet. Share an insight, caveat, or question.
Park et al. (2026) studied this question.