Answers are grounded in this paper and cite their sources.
Reliable determination of vitamin C in cosmetic products remains analytically challenging because of the susceptibility of l-ascorbic acid (AA) to oxidation and the complexity of cosmetic matrices. In this study, an ion-pair reversed-phase high-performance liquid chromatography method with diode-array detection (IP-RP-HPLC-DAD) was developed and validated for the determination of AA and total vitamin C after quantitative reduction of dehydroascorbic acid (DHAA) with tris(2-carboxyethyl)phosphine (TCEP). Validation according to ICH Q2(R2) and Eurachem guidelines confirmed method specificity without matrix interference at the AA retention time. The limits of detection and quantification were 0.7 and 2.2 mg/g for AA and 0.9 and 2.8 mg/g for total vitamin C, respectively. The method showed excellent linearity over concentration ranges of 2.2–200 mg/g for AA (R 2 = 0.9999) and 2.8–200 mg/g for total vitamin C (R 2 = 0.9999). The method demonstrated good accuracy (recoveries of 95.99–110.31%) and precision (RSD ≤ 4.73%). Processed samples remained stable in the autosampler at 4 °C for at least 9 h, with signal changes not exceeding 4.5%. The validated workflow was successfully applied to ten commercially available cosmetic products, demonstrating its suitability for routine compositional analysis and quality control of vitamin C-containing formulations.
No takes yet. Share an insight, caveat, or question.
Kurpet et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: