Answers are grounded in this paper and cite their sources.
Stability of plate osteosynthesis depends not only on plate strength but also on the implant–screw junction. Screw loosening, thread stripping, plastic deformation of the shaft or hole failure can result in loss of fixation and revision. Ti-6Al-4V remains the standard alloy for extra-osseous plates, yet its elastic modulus is substantially higher than that of cortical bone and favors stress shielding. Carbon composites offer high specific strength, biocompatibility, radiolucency and a modulus closer to bone; they are already used for osteosynthesis and defect reconstruction. Comparative data on the strength of the implant–screw junction in carbon-composite versus titanium bodies under identical loading remain scarce. Aim. To compare failure modes of implant–screw junctions in Ti-6Al-4V and carbon-composite implants and to relate screw deflection to static load. Materials and methods. Junction strength was tested on a modified servohydraulic machine (maximum force 10 kN) in cantilever bending. Screws of different lengths with a conical head thread were inserted into a full-size titanium implant and into a composite-body model of the same wall thickness and hole diameter. The composite body was a Ukraine-manufactured carbon–carbon composite previously used for extra-osseous osteosynthesis. Each material–overhang combination was tested on at least five identical specimens (n ≥ 5). Load was applied to the free end of the screw at lever arms of 14-, 22- and 24-mm. Force and deflection were recorded; testing stopped after failure of the junction or of the implant body. Results. Mean relative strength of the composite implant–screw junction was 78 %. Failure modes differed: composite body failed by hole-rim crushing or plate fracture; titanium screws failed by plastic deformation. The conical threaded interface remained intact in every material and overhang tested. Indicative material-level ratio (composite junction capacity vs. published cortical bone strength) was approximately 4.4 versus 5.6 for titanium; this ratio is not a safety factor of a complete bone–implant construct. Conclusions. Under ultimate load, the composite construct is inferior to the titanium construct but remains substantially stronger than cortical bone. Differences in failure mechanisms may be relevant for planning osteosynthesis and predicting the likely type of complication. A reduction in the construct’s load-bearing capacity could potentially be compensated by increasing the number of fixation points or by enlarging the plate’s cross-sectional dimensions.
No takes yet. Share an insight, caveat, or question.
Головаха et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: